Zero-water-peak fiber extends metro CWDM reach

Nov. 1, 2002

After being proposed to standards bodies only two years ago, coarse wavelength-division multiplexing (CWDM) is introducing low-cost, commercial multiwavelength optical systems into short- and medium-haul metro-edge networks. The availability of G.652C fibers, such as a zero-water-peak fiber (ZWPF), has increased the number of available CWDM channels throughout the optical spectrum compared to conventional single-mode fiber (CSMF).1 Further, ZWPFs lower the cost of deploying CWDM systems in metro networks.

In nonamplified CWDM, fiber attenuation, fiber-splice loss, connector loss, and mux/demux losses limit the attainable system reach. The system reach is also dependent on the number of channels and channel bit rate, which dictate the power budget of a transmitter/receiver pair. For example, a 16-channel 2.5-Gbit/s hubbed-ring network using optical add/drop filters at four nodes can be limited to approximately 40 km in circumference, depending on component insertion losses and power budgets. However, because a significant percentage of metro-edge rings exceed a perimeter of 40 km, it is beneficial to extend CWDM system reach and hence the number of applications for nonamplified CWDM technology.

A wavelength-assignment technique compensates for the attenuation slope in fiber and therefore increases the reach of metro-local or edge rings using nonamplified CWDM. Conventional SMF has a nominal attenuation of less than 0.4 dB in the 1300-nm window, approximately 0.3 dB in the 1550-nm window, and an attenuation peak around 1400 nm due to hydroxyl (OH-) absorption. Zero-water-peak fibers permanently eliminate the water peak, resulting in low loss at 1400 nm (see Fig. 1). Consequently, a ZWPF offers up to 33% more CWDM capacity than CSMF and supports all 16 ITU G.694.2 CWDM channels on a single fiber.

The 16 channels of the ITU G.694.2 CWDM wavelength grid extend from 1310 nm in the O-band to 1610 nm in the L-band with 20-nm channel spacing (see table) . In a ZWPF, maximum attenuation loss is at 1310 nm and decreases as 1/λ4 (due to decreasing Rayleigh scattering and elimination of the OH content) to a minimum around 1550 nm in the C-band. The loss then increases slightly between 1550 and 1610 nm in the L-band. Hence fiber transmission loss incurred by the CWDM wavelength channels around the ring is a maximum in the O-band and decreases to a minimum in the C- and L-bands.

On the other hand, mux/demux loss (including connector and splice losses) is a function of the number of mux/demux filter stages and the number of spans that a wavelength encounters on its path between transmission and reception. Therefore, CWDM wavelength channels should be assigned to the nodes to minimize the filter losses around the ring in the high-attenuation O-band and maximized in the low attenuation C- and L-bands. For such wavelength assignment, the mux/demux losses will compensate for fiber attenuation, minimizing the combined fiber and filter losses, thereby maximizing the ring perimeter.
A case study of a 16-channel 4-node CWDM hubbed-ring network employing ZWPF demonstrates a 25% extension of the ring perimeter applying an intelligent wavelength assignment. In this network, four local central offices (CO) transmit/receive signals from a tandem exchange hub, each on a different set of four wavelengths (see Fig. 2, left). This configuration is equivalent to a logical star network (see Fig. 2, right), except all 16 wavelengths can be physically supported on a single ZWPF. The hubbed-ring configuration allows for easy implementation of either unidirectional or bidirectional protection schemes. Here we will assume a unidirectional ring.

A four-CO system has four bands of 4-wavelength channels each (see table). All 16 channels are added/dropped from the network at the hub. Each of the central-office nodes will have three express/through bands (12 λs) and one add/drop band of CWDM channels (see Fig. 3). The design minimizes the number of filters encountered in add/drops between the hub and central office and back. For example, at CO 1, the drop channels encounter 4 filters (2 add/drop channel filters and 2 express-band filters) from the hub to CO 1, while the add channels encounter 10 filters from CO 1 to the hub. Thus, a higher filter insertion loss path is encountered going from the central office back to the hub.

In the worst-case assignment of channels, bands 1, 2, 3, and 4 traverse a total of 10, 8, 8, and 10 mux/demux filters from transmission to reception, respectively. Hence, bands 1 and 4 incur filter losses that are higher than the losses incurred by bands 2 and 3, since the latter traverse fewer nodes. Therefore, in a given loss budget, bands 1 and 4 have less power margin for fiber loss than bands 2 and 3. Because fiber attenuation is highest in band 1 (O-band), the maximum attainable ring perimeter is constrained by band-1 wavelengths.

An optimized wavelength assignment occurs when bands 1, 2, 3, and 4 traverse 8, 8, 10, and 10 mux/demux filters from transmission to reception, respectively. Therefore bands 3 and 4 incur higher filter losses than bands 1 and 2. Hence, for a given loss budget, the higher-attenuation band 1 and 2 (O- and E-bands) are given more power margin for fiber loss than the lower-attenuation bands 3 and 4 (S-, C- and L-Band). Therefore, higher fiber loss in the O- and E-bands is counterbalanced by lower filter losses to minimize the total ring loss and maximize the ring perimeter.

RING PERIMETERThe ring perimeter is calculated from:
where n = 4 is the total number of central offices in the hubbed ring, P = -1 dBm is the optical source power, S = -29 dBm is the avalanche photodiode (APD) receiver sensitivity of a typical 2.5-Gbit/s APD, F(k) is the worst-case mux/demux filter loss incurred by wavelength channel λi assigned to CO k, C(k) is the total connector loss incurred by wavelength channel λi assigned to CO k (assume a 1-dB connector loss per span), and A(λi) is the fiber attenuation at wavelength λi. Assuming a 1-dB system margin for splicing and so forth, the loss budget is 28 dB.

In the worst-case channel assignment, by including the connector loss and a 1-dB power margin for splicing, mux/demux filter loss for bands 1 and 4 is 15.5 dB. For the available budget of 28 dB, this leaves 12.5 dB for fiber loss. The attained ring perimeter is limited to 48 km by the O-band channel, λi, at 1310 nm (see Fig. 4).

In the optimized channel-assignment case, the filter loss for bands 1 and 4 are 12.5 and 15.5 dB, respectively, which leaves 15.5 dB for fiber loss in the O-band. The lower filter loss of 3 dB in the O-band compensates for the higher fiber attenuation in the O-band, consequently maximizing the ring perimeter. The attained ring perimeter reaches 60 km in channel λi = 1310 nm, a full 25% extension compared to the worst-case channel assignment.

Charles Ufongene is a systems engineer, metro optical networking, at OFS, 19 Schoolhouse Road, Somerset, NJ. Raymond Boncek is a systems engineering manager at OFS in Norcross, GA. Charles Ufongene can be reached at [email protected].

  1. G. Keiser, Optical Fiber Communications., 93, McGraw-Hill 3rd Ed. (2000).

Sponsored Recommendations

On Topic: Fiber - The Rural Equation

Oct. 29, 2024
RURAL BROADBAND:AN OPPORTUNITY AND A CHALLENGE The rural broadband market has always been a challenge for service providers. However, the recent COVID-19 pandemic highlighted ...

How AI is driving new thinking in the optical industry

Sept. 30, 2024
Join us for an interactive roundtable webinar highlighting the results of an Endeavor Business Media survey to identify how optical technologies can support AI workflows by balancing...

The AI and ML Opportunity

Sept. 30, 2024
Join our AI and ML Opportunity webinar to explore how cutting-edge network infrastructure and innovative technologies can meet the soaring demands of AI memory and bandwidth, ...

ON TOPIC: Cable’s Fiber to the X Play

Aug. 28, 2024
Cable operators are strategically deploying fiber-to-the-home (FTTH) networks in Greenfield markets and Brownfield markets where existing cable plant has reached its end of life...